Applications
Design of a Double-Suction Fan Stage
Design of a Cooling Fan
Design of Refrigeration Compressor Stage in R134a
Design High Performance Centrifugal Compressor Impellers
Design High Performance Centrifugal Compressor Vaned Diffusers
Design of High Performance Pump Stage
Design of an Automobile Torque Converter
Design Optimisation of a Strongly Interacting Diffuser Pump Stage
Design of a Double-Suction Volute Pump
Redesign of an Industrial Compressor Stage
Multi-Objective Optimisation of a Centrifugal Pump Stage by Means of Design of Experiment Coupled with Inverse Design Method
Hydraulic Design Optimisation of a Torque Converter
Design of a 3 Stage Axial LP Turbine for Aeroengine Applications
Design of an Inducer Pump with High Suction Performance and Backflow Control
Design High Efficiency Impellers with Splitter Blades
Design High Performance Axial Turbine Stages with More Uniform Exit Flow
Publications
- Design of a Box Fan Rotor Using 3-D Inverse Design Method
- Design of axial fan using inverse design method
- Design of A Propeller Fan Using 3-D Inverse Design Method and CFD for High Efficiency and Low Aerodynamic Noise
- Optimization of fan noise by coupling 3D invese design and automatic optimizer
- Choice of Optimum Blade Loading in Application of 3D Inverse Design to Design of Pumps and Fans.
Case Studies
- TURBOdesign1 an efficient design tool for the development of compact fan guide vanes at ebm-papst
- Coupling TURBOdesign1 with automatic optimisation at Ebm-Papst to design efficient and low cost centrifugal fans
- Designing Optimal Fans Using TURBOdesign1 at Ebm-papst Mulfingen
- Inverse Design of Aeronautical Turbines in Avio S.p.A Design Process
- Design of a Compact Reactor Coolant Pump with Higher Efficiency and Cavitation Performance by using TURBOdesign1
Home » Case Studies » TURBOdesign1 Application Used in Ebara Shinwa Cooling Tower Fan
TURBOdesign1 Application Used in Ebara Shinwa Cooling Tower Fan
Hiroshi Sugawara, Development Division Executive
Ebara Shinwa Ltd. Japan
|
Ebara Shinwa, founded in 1952 and one of the Ebara Group Companies, is a top manufacturer of cooling towers for air conditioning systems in Japan. The recent strong demand for energy-saving and en vironmentally friendly products, particularly in reference to improvements in efficiency and noise reduction of axial flow fans used in the cooling tower, have become crucial. Ebara Shinwa therefore decided to carry out a project for redesigning the current fan model using TURBOdesign1 as well as to clarify the impact of this new technology on their products line.
|
|
ShareThis: